So, if you need to get into Apt A, you revolve to the door of apartment A. That room revolves, and can give you access to any apartment. In the center you have a round hall/room where all the apartment doors can be accessed, but you only have one door in the round hall. So first, let's pretend that you have a round building with apartments all along the outer edges of the building. Anyone who is familiar with the device, will figure out what I mean without my blatantly letting unscrupulous characters into the knowledge of it. Now that I have your interest peaked, I will describe what I mean using a picture example. REMOVING A PROGRAMMED ZONE IN A GE NETWORX NX 148E HOW TOBut, I did mention this, "You just need to know how to use it." Well Les, no, there isn't anything in the programming that lets you ignore the access code. The bottom line is that you probably just want to save money. Therefore, you don't know what you are missing. But then again, you are obviously not getting monitoring. You do want your family safe from burglars and fires, right? There are a lot of things to know about programming that only comes with experience. I just hope that you understand that programming a msinboard is not for novices. It is a little slower than getting into a Honeywell panel, but the few minutes is well worth it.įor thrifty homeowners: And yesss, home owners should buy a new board. This way, you save programming the board from scratch just make sure you still check every location though. It makes Networx/Caddx panels take-over-able very quickly. REMOVING A PROGRAMMED ZONE IN A GE NETWORX NX 148E CODEWith it, you do not need to know what any master, installer, or download access code is. It is best used for direct access to a locked board. It has the ability to store 4 separate panel configurations to quickly upload to a panel onsite, if you require that. Used to do much the same thing with the old FBII XL4 except that theĮxpansion modules for it still required panel power as did all theįor alarm installers: The direct connect module just hooks up to the board keypad wiring and can connect to the laptop thru a usb port. On the main panel because it had its own power supply. How much you ran off the expansion modules it only put a single keypad load Wires (heavier gage) back to the main panel in the main building. I liked the NX8E myself because I could put a selfĬontained and self powered expansion module in another building and wireĮverything up almost like it was its own alarm panel, and then just run 4 Modules, keypads, and accessories that were on the system, but may not haveīeen at the main panel. The biggest headache you get when you do a board swap is finding any and all I used a US Robotics Sportster to download Overlord) download remotely just fie with many more readily available and REMOVING A PROGRAMMED ZONE IN A GE NETWORX NX 148E SERIESThe NX series of panels from Caddx (and I am pretty sure their newer I'm pretty sure NX-588E is the direct link module. REMOVING A PROGRAMMED ZONE IN A GE NETWORX NX 148E MANUALPress - to program functions of the NX-8 master control panel itself.Įnter the location number you wish to display/alter, followed by the Įnter the desired new data, followed by the key.Īfter you press the key the program will advance to the next segment.Ĭhange it if needed and press to scroll on.įor more detailed instructions, see page 9 of the manual I referenced above.ĩ4 wrote in and swap out the board, much less hassle To change any item, enter programming as follows: This is the code you use to enter programming Follow the instructions for changing that value alone.Īnother significant code is the "Go To Program" code, found in location 42. If all you want is to change the Download Access Code, that is stored in Please be absolutely certain this is what you want to NOTE: Doing this will clear the program, requiring you to program the entire Go to page 8 andįollow the instructions for "Loading Factory Defaults" in the center of the You want to do, click the following link for the manual. Do you want to do a "factory default" on the NX-8 panel? If that is what
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |